PT Round - PTC/MECH/LDCL/001
PT Item - 20210 S BEAM LOAD CELL; Display – 50000 counts as per load cell cap. In N Divisions: 50000; Resolution: 1Division
Parameter - Force up to 500 N
Participation Criteria - The participant laboratory's CMC should be greater than 0.03% rdg
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration -Open
PT Round - PTC/MECH/PLRG/001-2
PT Item - UPTO THREE SIZES
Parameter - Diameter
Participation Criteria - The participation Laboratory should have CMC > 0.7 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/MISS/001
PT Item - Micrometer Setting Standard 25 mm & 75 mm
Parameter - Length
Participation Criteria - The CMC of participating lab. should be > 1.1 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/PLPG/001
PT Item Description - Outer Diameter Plugs / Plain Plug Gauge of sizes 5 mm,36.5mm and 98 mm
Parameter - Out Side Diameter
Participation Criteria - The participant laboratory should have CMC greater than 1 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/TPPG/001
PT Item Description - Taper Plug Gauge of sizes ø 50mm & Angle 7° & ø 38mm & Angle 3.5°
Parameter - Diameter & Angle
Participation Criteria - The participant laboratory should have CMC greater than 1.4 μm and Angle 18"
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/TPRG/001
PT Item Description - Taper Ring Gauge of sizes ø 35mm & Angle 2.5° & ø 25mm & Angle 1°
Parameter - Diameter & Angle
Participation Criteria - The participant laboratory should have CMC greater than 1.8 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/PLDG/001
PT Item - Analog Plunger Dial Gauge L.C. 0.001 mm ;Range 0 to 1 mm
Parameter - Instrumental Error
Participation Criteria - the CMC of participant laboratory should be greater than 1 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - -PTC/MECH/PRVC/002
PT Item Description - Digital pressure indicating device, L.C. 0.01 bar, operating range 0-50 bar
Parameter - Pneumatic Pressure - Range:0 to 35 bar
Participation Criteria - Participant laboratory should have Unc. of measurement Coarser than 0.008 % rdg
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration- Open
PT Round - PTC/ELTC/PCTI/001
PT Item - Process Calibrator Type K TC | RTD PT 100 | Type J TC | Type S TC (Make: Victor 14 + Multifunction Calibrator)
Range and Resolution - Thermocouple - 0.1℃/1℃ | RTD 0.1℃
Parameter - Temperature Simulation
Participation Criteria - The participation Laboratory should have uncertainties > 0.15 °C for Type K TC| 0.09 °C RTD PT 100 | 0.12 °C for Type J TC| 0.48 °C for Type S TC.
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open*(This PT Item has waiting period of 3-5 months due to more no. of participants)
Select options
This product has multiple variants. The options may be chosen on the product page
PT Round - PTC/MECH/PSPL/001
PT Item - Push-pull gauge (Force Gauge - up to 1000N) L.C. 0.1 N
Parameter - Force
Participation Criteria -The Participating Laboratory should have CMC > 0.01%
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/THER/TEMP/001
PT Item Description - 4 Wire Sensor, Class 2, Digital indicator of L.C.0.01°C , Probe Diameter – 6 mm, Length – 300mm, Minimum insertion length – Participant has to decide as per facilities, Wire wound Sensor, Length of wire – 2Ft
Parameter - Temperature Range : 50°C to 250°C
Participation Criteria - The Participant Laboratory's CMC should be greater than 0.08°C
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/THER/TCPL/001
PT Item - S Type Thermocouple
Parameter - Temperature up to 1000 °C
Participation Criteria - the participant laboratory should have CMC > 1.5 °C
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open