PT Round - PTC/MECH/SUPL/001
PT Item Description - Granite Surface Plate 1000 X 600 mm (This is an onsite PT activity, where participants needs to carry their instrument to Octagon's Laboratory at Pune and perform measurements).
Parameter - Flatness
Delivery - Lab code will be delivered within 7 working days
Participation Criteria - The participant laboratory should have CMC coarser than 3.5 μm
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/THPG/001
PT Item - Taper Thread Plug Gauge
Parameter - Effective Diameter
Participation Criteria -The CMC of participating lab. should be > 2.5 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
The Registration is Open
PT Round - PTC/MECH/DIMN/001
PT Item - Thread Plug Gauge up to 50mm
Parameter - Simple Effective Diameter
Participation Criteria - The CMC of participating lab. should be > 2.3 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/PTRG/001
PT Item - Thread Ring Gauge with form error less than 1 μm
Parameter - Simple Effective Diameter for sizes M 5 X 0.8 -6g NOGO, M 40 X 3.0 -6g GO and G3 B ISO-228 NOGO Thread Ring Gauges
Participation Criteria - The participant laboratory's CMC should be greater than 1.4 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/TOSN/001
PT Item - Torque Sensor up to 1000Nm - Measurement Points 100,250,450,750 & 950 Nm
Resolution - 0.1 Nm
Parameter - Torque
Participation Criteria - The CMC of participating lab. should be >0.03%
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Last date of Registration - Open
PT Round - PTC/MECH/PRVC/003
PT Item Description - Digital Vacuum Gauge, Operating range -1 to 3 bar, L.C. 0.01 bar
Parameter - Vacuum - Range:-1 to 0 bar
Participation Criteria - Participant laboratory should have Unc. of Measurement greater than 0.009% rdg
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/WEBL/001
PT Item Description - Digital Weighing Balance RADWAG Make
Option 1. Max. 220.0 g with readability 0.1 mg
Option 2. Max. 3000 g with readability 1 mg
Parameter - Mass
Delivery - Lab code will be delivered within 7 working days
Participation Criteria - The participant laboratory should have CMC for coarser than
For balance of 220 g - 0.025 mg
For balance of 3000 g. - 42 mg
The participating Laboratory should carry their E1 class weights to Octagon Site for calibration of weighing balance up to 3000 g. A schedule will be shared to each participant laboratory.
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
Select options
This product has multiple variants. The options may be chosen on the product page
PT Round - PTC/MECH/MASS/001
PT Item - Weights
Parameter - Mass 2g (E1 Class), 20g (E1 class), 200g (E1 Class) and 500g (E2 Class)
Participation Criteria - The participant laboratory's CMC should be greater than 0.003 mg for 2 g, 0.006 mg for 20g , 0.027 mg for 200 g & 0.26 mg for 500g weight.
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open