PT Round - PTC/ELTC/TIME/001
PT Item - Digital Timer - Selec - Model XT546BX
Resolution - 0.01sec
Parameter - Time
Participation Criteria - For Range 1 Sec to 600 Sec -> The participating Laboratory should have Estimated uncertainty > 0.12 Sec - 0.70 Sec
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open*(This PT Item has waiting period of 3-5 months due to more no. of participants)
PT Round - PTC/MECH/TORQ/001
PT Item - Torque Wrench 500 Nm - Measurement Points 50,300,500 Nm
Resolution - 0.1 Nm
Parameter - Torque
Participation Criteria - The CMC of participating lab. should be >0.1%
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Last date of Registration - Open
PT Round - PTC/MECH/FEEG/001
PT Item Description - Feeler Gauge of three different sizes up to 1 mm
Parameter - Thickness
Participation Criteria - The participant laboratory should have CMC coarser than 0.7 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/GABL/001
PT Item - Gauge Block (Tungsten Carbide)
Parameter - Central Length Deviation for 1.5,40and 90 mm
Participation Criteria - The participant laboratory's CMC should be greater than 0.04 + L/ 3000 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/ELTC/HVTS/001
PT Item - HV Probe of Agilent make with 3 1/2 Resolution DMM Fluke 17B+
Parameter - DC High Voltage 1 to 40kV , AC High Voltage 1 to 28 kV
Participation Criteria - The participant laboratory's CMC should be greater than 1.4% for AC & DC High Voltage
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/PRVC/004
PT Item Description - Digital Hydraulic Pressure Indicating Device, Operating Range 0 to 700 bar, L.C. 0.01 bar, Accuracy ± 0.1% FS
Parameter - Hydraulic Pressure - Range:0 to 700 bar
Participation Criteria - Participant laboratory should have CMC greater than 0.009 % rdg
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/PRVC/005
PT Item Description - Digital Hydraulic Pressure Indicating Device, Operating Range 0 to 200 bar, L.C. 0.01 bar, Accuracy ± 0.1% FS
Parameter - Hydraulic Pressure - Range:0 to 200 bar
Participation Criteria - Participant laboratory should have CMC greater than 0.009 % rdg
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/THER/HYGR/001
PT Item - Digital Temperature Humidity meter, Make: Polltech, Model: PSI-RHT 1B (TT), Range: -40 to 60°C, Resolution: 0.01°C,
0 to 100 % RH, Resolution: 0.01%RH, Accuracy: +/- 0.2°C, 0.8% RH
Parameter - Humidity 20%Rh, 30%Rh,50%Rh, 70%Rh & 80%Rh @ 25°C
Participation Criteria - The participant laboratory's CMC should be greater than 0.45 %Rh
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/THER/HYGR/001
PT Item - Digital Temperature Humidity meter, Make: ETI Ltd UK, Model: 6100, Range: 5 to 50 °C, 20 to 95%Rh Resolution: 0.1%Rh,
Parameter - Humidity 20%Rh, 30%Rh,50%Rh, 70%Rh & 85%Rh @ 25°C
Participation Criteria - The participant laboratory's CMC should be greater than 0.45 %Rh
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/THER/IRSN/001
PT Item - IR Sensor of ETI make, Raytemp28, Range: -50 to 1370°C, Resolution:0.1°C , Accuracy: +/- 2 % rdg. or 2°C whichever is greater.
Parameter - Temperature at 50°C, 100°C, 150°C,300°C and 500°C at emisivit 0.95
Participation Criteria - The participant laboratory's CMC should be greater than 2.44 °C
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/ELTC/LCRM/001
PT Item - LCR Meter - BK Precision - Model 878B (Handheld LCR MEter)
Resolution - 40,000 counts resolution on primary and 10,000 counts resolution on secondary display
Parameter - Resistance, Capacitance & Inductance @ 1KHz: Alternating Current (< 1GHz)
Participation Criteria - The participation Laboratory should have estimated uncertainties >
For Range 100 uH to 1 H - Inductance 0.09% to 0.386% | For Range 1nF to 1 uF - Capacitance 0.061%
For Range 1 Ω to 10KΩ - AC Resistance 0.07%
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open
PT Round - PTC/MECH/LEDG/001
PT Item - Analog Lever Dial Gauge L.C. 0.01 mm ;Range 0 to 0.8 mm
Parameter - Instrumental Error
Participation Criteria - the CMC of participant laboratory should be greater than 1.4 μm
Delivery - Lab code will be delivered within 7 working days
Note: Participation criteria defined above, is based on present NABL practice of ILC, where CMC of reference lab should be superior (smaller measurement uncertainty) than the participant’s CMC. All Participant labs should ensure that the participation criteria have been met while applying for the PT. The participant lab should not report estimated uncertainty, superior than accredited CMCs for that parameter for PT measurements. If Estimated uncertainty is coarser to accredited CMCs then Estimated uncertainty should be reported by the participant laboratory.
Registration - Open